The short version of peptide hormone fits in a sentence. The long version — which is the one that helps — is below.
This page was last updated on 2026-04-06 and is reviewed periodically as new material appears.
Regulatory status: AOD-9604 is not approved as a therapeutic drug in the United States, European Union, or other major markets. It is listed by the World Anti-Doping Agency as a prohibited substance in sport, specifically under growth hormone fragments. Many jurisdictions restrict its sale for human consumption. Products marketed online may not meet pharmaceutical quality standards. The legal status varies by country and often depends on whether the material is presented as a research chemical, supplement, or drug.
Detection and characterization of AOD-9604 in research and anti-doping settings typically rely on mass spectrometry coupled with liquid chromatography. These methods can identify the peptide by its mass and fragmentation pattern. Immunoassays may also be used in some screening contexts, but they can cross-react with related peptides. Because the molecule is small and may be present at low concentrations, sample preparation and method validation are important. Confirmatory analysis usually requires comparison with a certified reference standard.
Clinical development of AOD-9604 included trials in people with obesity. Reports from early-phase and mid-phase studies described modest or inconsistent changes in body weight. A phase IIb program did not meet its primary endpoint, and the compound was not approved for medical use. Differences in formulation, delivery route, and participant characteristics may explain some of the variation. Later investigations explored whether the peptide might have effects in other tissues, including cartilage.
Regulatory treatment of AOD-9604 is shaped by its classification as a peptide hormone. The World Anti-Doping Agency lists it as a prohibited substance, and many national anti-doping organizations adopt that list. It does not hold approval as a prescription medicine in the United States, the European Union, or other major markets. Products sold online are frequently labeled for research use only and may not undergo independent quality testing. Import and possession rules differ by country, so legal status depends on local law.
| Property | Value | Notes |
|---|---|---|
| Regulatory status | Not approved as a medicine | Status varies by country; prohibited in sport. |
| Common storage temperature | 2–8 °C for lyophilized powder | Protect from light and moisture; follow supplier instructions. |
| Typical analytical method | LC-MS/MS | Used for identification and quantification in biological samples. |
| Purity assessment | HPLC and mass spectrometry | Reverse-phase HPLC is common for peptide purity. |
| Common synonyms | AOD9604; hGH 176-191 fragment | Naming conventions differ across studies. |
AOD-9604 is a synthetic peptide modeled on the C-terminal region of human growth hormone. It is often described as hGH fragment 176-191. Research interest arose because it was designed to isolate possible effects on fat metabolism from other actions of growth hormone. It is not a full growth hormone molecule. Its development history includes early laboratory and animal studies followed by human trials. The peptide has been examined in laboratory, animal, and limited human studies.
The compound has been studied as a potential treatment for obesity and related metabolic conditions. Published trials have examined changes in body weight, fat mass, and safety markers over limited durations. Results have been mixed or modest, and no large-scale outcome trials are established. Regulatory agencies in several countries have not approved it as a therapeutic drug. Some commercial products have been marketed outside regulated pharmaceutical channels, which raises questions about quality and claims.
In the scientific literature, AOD-9604 appears in reviews of growth hormone fragments and in discussions of peptide-based metabolic research. Some sources distinguish it from growth hormone itself, while others group it with compounds marketed for weight management. The evidence base is small compared with approved obesity medications. Questions about long-term efficacy and clinical relevance remain open, and independent replication of key findings is limited. Most published reports are early-stage and exploratory.
Stability of AOD-9604 depends on storage conditions. Lyophilized powder is generally more stable than reconstituted solution. Recommended storage is typically at -20°C or lower, protected from light and moisture. Repeated freeze-thaw cycles can cause aggregation or degradation. In solution, the peptide may be susceptible to hydrolysis or oxidation, so aliquoting and cold storage are common practices. Researchers often add stabilizers such as mannitol or trehalose during lyophilization to improve shelf life.
Quality control for AOD-9604 involves verifying identity, purity, and concentration. Suppliers may provide a certificate of analysis listing HPLC purity and mass spectrometry data. Independent verification is advised because peptide products can vary in quality. Researchers should check for counterions, residual solvents, and microbial contamination. Proper documentation supports reproducibility and safety in laboratory studies. When sourcing, institutions often require third-party testing and detailed chain-of-custody records. These steps help ensure that experimental results are attributable to the peptide rather than impurities.
Analytical characterization of AOD-9604 typically employs reversed-phase high-performance liquid chromatography (RP-HPLC) to assess purity and identity. Mass spectrometry provides confirmation of molecular mass, while amino acid analysis can verify composition. These methods are standard for peptide research chemicals. Because the peptide lacks a distinct chromophore, detection often relies on ultraviolet absorbance at 214 nm or mass spectrometric response. Laboratories may also use capillary electrophoresis for separation. For example, size-exclusion chromatography can detect aggregates.
Water soluble drugs might form eutectic mixtures and not freeze adequately, so dose is limited to 60 mg and the maximum drug limit is 400 mg for water insoluble drug as large particle sizes might present sedimentation problems during manufacture.
=== Polymer chemistry === Although MS-based analyses of polymers have largely been performed using single-stage MS, tandem MS has also been used to characterize polymer components. CID is the most common method of dissociation used, but ETD has been used as a complementary method. Unique bond cleavages resulting from ETD supply valuable diagnostic information.
Das RC, Heath EC (1980). "Dolichyldiphosphoryloligosaccharide--protein oligosaccharyltransferase; solubilization, purification, and properties". Proc. Natl. Acad. Sci. U.S.A. 77 (7): 3811–5. Bibcode:1980PNAS...77.3811D. doi:10.1073/pnas.77.7.3811. PMC 349716. PMID 6933437.
=== In biomedical science === In the biomedical sciences, PVDF is used in immunoblotting as an artificial membrane (usually with 0.22 or 0.45-micrometre pore sizes), on which proteins are transferred using electricity (see western blotting). PVDF is resistant to solvents and, therefore, these membranes can be easily stripped and reused to look at other proteins. PVDF membranes may be used in other biomedical applications as part of a membrane filtration device, often in the form of a syringe filter or wheel filter. The various properties of this material, such as heat resistance, resistance to chemical corrosion, and low protein binding properties, make this material valuable in the biomedical sciences for preparation of medications as a sterilizing filter, and as a filter to prepare samples for analytical techniques such as high-performance liquid chromatography (HPLC), where small amounts of particulate matter can damage sensitive and expensive equipment. PVDF transducers have the advantage of being dynamically more suitable for modal testing than semiconductor piezoresistive transducers and more compliant for structural integration than piezoceramic transducers. For those reasons, the use of PVDF active sensors is a keystone for the development of future structural-health monitoring methods, due to their low cost and compliance.
Sources: en.wikipedia.org
FID measurements are usually reported "as methane," meaning as the quantity of methane which would produce the same response. The same quantity of different chemicals produces different amounts of current, depending on the elemental composition of the chemicals. The response factor of the detector for different chemicals can be used to convert current measurements into actual amounts of each chemical. Hydrocarbons generally have response factors that are equal to the number of carbon atoms in their molecule (more carbon atoms produce greater current), while oxygenates and other species that contain heteroatoms tend to have a lower response factor. Carbon monoxide and carbon dioxide are not detectable by FID. FID measurements are often labelled "total hydrocarbons" or "total hydrocarbon content" (THC), although a more accurate name would be "total volatile hydrocarbon content" (TVHC), as hydrocarbons which have condensed out are not detected, even though they are important, for example safety when handling compressed oxygen.
Christianity does not require male circumcision, with covenant theology teaching that the Christian sacrament of baptism fulfills the Israelite practice of circumcision, both being signs and seals of the covenant of grace. Most mainstream Christian denominations currently maintain a neutral position on the practice of non-religious circumcision. Male circumcision is commonly practiced in many predominantly Christian countries and many Christian communities. In the Coptic Orthodox Church, the Ethiopian Orthodox Church and the Eritrean Orthodox Tewahedo Church male circumcision is an established practice, and require that their male members undergo circumcision, and it is seen as a rite of passage. While male circumcision is widely practiced by the Druze, the procedure is practiced as a cultural tradition, and has no religious significance in the Druze faith. There is no special date for this act in the Druze faith: male Druze infants are usually circumcised shortly after birth, however some remain uncircumcised until the age of ten or older. Some Druzes do not circumcise their male children, and refuse to observe this "common Muslim practice".
=== Amputation as punishment === There is evidence of amputation as punishment dating back to 1750 BCE. The Babylonian Code of King Hammurabi sanctioned amputation as a punishment. Amputation as a punishment continued in ancient Peru, where the part of the body amputated had a connection to the crime committed (for example, stealing might be punished by amputating the hand of the guilty). Amputation continued as a form of punishment into the Roman period as well as the Byzantine period, but became less prominent after the collapse of the Byzantine Empire. These punishments increased again during the Middle Ages, but declined again after perceptions of punitive amputation changed significantly during the Renaissance and Enlightenment. In medieval Europe, corpses would sometimes be amputated after death as a form of public shaming or punishment. Medieval Christians believed strongly in the importance of bodily integrity, even after death; therefore, post-execution dismemberment reflected the expectation of eternal damnation for the worst criminals. There is also documentation of nose amputation being used as a form of punishment or retaliation. In France during the 5th and 6th centuries, nose cutting was prominent enough to be classified as its own crime, which would result in a serious fine to the perpetrator. However, it was also occasionally used as a punishment for serious crimes such as threatening royals.
Sources: en.wikipedia.org
No major regulatory agency has approved AOD-9604 as a medicine. It is treated as an experimental peptide in research settings. Some countries restrict its sale or import.
The World Anti-Doping Agency classifies growth hormone fragments, including AOD-9604, as prohibited substances. The classification reflects concern about potential performance-enhancing use. Athletes are subject to testing for such peptides.
Detection typically uses liquid chromatography combined with mass spectrometry. These methods separate the peptide and identify it by mass. Immunoassays may screen samples but require confirmation by a more specific technique.
No. Major drug regulators have not approved AOD-9604 for weight loss or any other therapeutic indication. It remains an investigational compound studied in research settings.